Ondersteunde Apparaten

Device TypeModbus TCP (Ethernet)RS485Curtailment
MIC 600TL-X
MIC 750TL-X
MIC 1000TL-X
MIC 1500TL-X
MIC 2000TL-X
MIC 2500TL-X
MIC 3000TL-X
MIC 3300TL-X
Afbeelding 1

Bekabeling

RS485

RS485 Wiring
  • For correct RS485 wiring: Follow the guidelines for RS485 wiring.
  • If the wiring shown in the table below is incorrect, please let us know.
  • There is no general consensus in the industry about the usage of A and B for the RS485 polarity, so it may be counterintuitive and opposite of what you might expect for some devices.
DeviceSmartgridOne Controller model OM1SmartgridOne Controller model IG8RS485-USB converterRS485-Ethernet converter
RS485 A1 RS485 ARS485_POSRS485 ATX+
RS485 B1 RS485 BRS485_NEGRS485 BTX-
N/B RS GNDGNDNot availableG

Configuratie

NOTE: RS485 Device Addresses
  • You MUST give each device on the RS485 bus a unique address. Check the manual of the device on how to do this.
  • Use lower addresses first (1, 2, ...) because the SmartgridOne Controller will find them faster!
  • For each device, it is generally recommended to stick with the factory default baud rate, parity, and stop bits. The SmartgridOne Controller will scan on those first.

Standaard is de omvormer ingesteld op adres 1. Dit kan worden gewijzigd via het instellingenmenu van de omvormer. Dit is alleen nodig als meerdere apparaten zijn aangesloten op de RS485-communicatiebus.

U kunt het adres van de omvormer wijzigen via de aanraakbediening. Het werkt als volgt:

AanraakbedieningImpact
Eenmaal aanrakenWijzig weergave of nummer + 1
Tweemaal aanrakenInvoer of bevestigen
Drie keer aanrakenVorig menu
5 seconden ingedrukt houden
  • Bevestig landinstelling of nummer.
  • Herstel standaardwaarde.

Verander het adres door naar het menu "Set Comaddr" te gaan, zoals weergegeven op de afbeelding links of hierboven. Zet het adres op een unieke waarde. Zie Hoofdstuk 7 van de omvormermanual voor meer informatie.